Robinson Theater Technical Specifications
-
Seating Capacity
Orchestra: Section 100 - House Right: 129
Section 200 - Center: 136
Section 300 - House Left: 129
ADA Spaces for Wheelchairs/Scooters: 6
Orchestra Total: 400
Balcony:
Section 100 - House Right: 152
Section 300 - House Left: 152Balcony Total: 304
TOTAL SEATING: 704 -
Rigging Specifications
SINGLE PURCHASE, HAND OPERATED LINE SETS. OPERATED FROM STAGE FLOOR STAGE RIGH.
NUMBER OF AVAILABLE LINESETS: 18
BATTEN LENGTH: Varies between 24’6” and 39”
-
Lineset Schedule
Stage opening is 31’ from wing to wing
0'-0" Plaster Line
1 1'-5" House Curtain/ fire curtain
2 2'-10" Leg 1
3 3'-6" NO LINESET
4 4'-0" NO LINESET
5 4'-6" 1st Electric
6 5'-6" XXXXXXXX
7 6'-6" Movie Screen, projectable surface 21’H x 27’8”W
8 7'-0" Border 1
9 7'-6" NO LINESET
10 8'-5" Leg 2
11 9'-6" 2nd Electric
12 10'-6"
13 11'-0" Center Mid/ Border 2
14 11'-6" NO LINESET
15 12'-0" Leg 3
16 12'-6" 3rd Electric
17 13'-0 NO LINESET
18 13'-6" Projection Screen 12’H x 9’W
19 14'-0” NO LINESET
20 14'-6" Border 3
21 15'-0" CYC Electric
22 15'-6" XXXXXXXXX
23 16'-0"
24 16'-6" NO LINESET
25 17'-0"
26 17'-6" Cyclorama 40’W x 24’H, curved -
Lighting System
Console: ETC Gio@5
2 Universal Fader wings 2x20
2 touch screen monitorsDimmers: ETC Sensor SR3-48
20 Sensor R20AF- Dual 20A relay modules
22 Sensor TR20AF- Dual 20A Thru-relay modules
*system allows for both conventional and intelligent/LED lighting controlUnison Paradigm Architectural Lighting system- 4 house light controllers located throughout theatre.
LED Fixtures:
6 - Source4Lustr Series 2 50deg
18 - Source4Lustr Series 2 26deg
30 - Source4Lustr Series 2 19deg
5 - Source4Lustr CYC adapters
15 - Chauvet Colordash Par Hex 12 -
Audio
Yamaha LS9-32
DAS Variant series compact line array with flown subwoofers
Rehnkus Heinz monitor boxes with QSC power amps
Up to 8 monitor mixes available on and backstage
Clear-com party line communication system with beltpacks and headsets as needed
SHURE ULXP wireless microphone system
An extensive microphone inventory with various condenser and dynamic microphones
High quality microphone stands
Powered and unpowered hotspot monitors
Small/medium portable full range sound system
Listen Systems assistive listening devices
iMac FOH playback computer with Qlab basic license and SHURE wireless workbench.
Rackmount CD player for playback at FOH
All necessary microphone and monitor cable for full system implementation
Various adapters and audio problem solvers. -
Loading Dock
The loading dock is located behind the Robinson Theater (Building 14A), where building connects to the Fine Arts Center (Building 45). The dock is shared between Robinson Theater and Lazzara Performance Hall. There are two bays, and one side is equipped with a dock leveler. The dock measures 3 feet, 3 inches high with 2443 square feet of receiving room. Each loading door is 10 feet wide by 12 feet high.
The dock area is adjacent to a circular driveway that allows turning space for buses and large trucks. The dock is typically accessible via Lot 12, which is the parking lot for Osprey Village residence hall complex, which is located behind the Fine Arts Center. The dock is also accessible via the driveway that runs along the perimeter of the Fine Arts Center Parking Garage (Garage 44), which dead-ends behind the Fine Arts Center at the loading dock. If access is blocked due to construction or other activities, the technical director will notify clients in advance.
-
Bus & Truck Parking
Limited bus and truck parking is available at the venue with advanced notice. Additional or long-term parking for buses and trucks is available at Lot 53, which is located at Hicks Hall off Kernan Boulevard. Please contact the technical director or event coordinator to arrange for parking. -
Dressing Rooms
The Robinson Theater has three dressing rooms that are available for rental. There is a small dressing room located off stage left on the first floor (Room 1317), but it does not have a restroom. There are two dressing rooms (Rooms 2325 and 2327) with restrooms and a shower located off stage left on the second floor. -
Green Room
A small Green Room (Room 1316) is located off stage left on the first floor. The Green Room is included in the rental of the Robinson Theater. The room is outfitted with a leather love seat and club chair and small side tables. The room features a wall of windows, which have curtains that can be closed for privacy. The Green Room also includes a door that leads to the back of the Orchestra Section 100 in House Right.